Multi-Point Transformer Hot Spot Monitor
Multi-channel hot spot acquisition for phase, winding and cooling-zone comparison.
Dielectric winding-tube sensor for direct transformer hot-spot measurement in strong electromagnetic fields.

Dielectric winding-tube sensor for direct transformer hot-spot measurement in strong electromagnetic fields.
FUZHOUINNO reviews the sensor arrangement, channel count, installation environment and communication requirements for each transformer project.
Request Product Configuration| Temperature Range | -40°C to +240°C (Customizable for higher temperature range) |
|---|---|
| Temperature Resolution | 0.1°C |
| Temperature Measurement Accuracy | ±1°C (Can be customized for higher accuracy) |
| Standard Fiber Length | 3m (Customizable length available) |
| Fiber Type | Polyimide |
| Fiber Sheath | PTFE |
| High Voltage Resistance | 100KV |
| Response Time | <100ms |
| Sensing Technology | Rare Earth Fluorescence |
| Signal Processing | All-optical signal temperature measurement |
| Connector Type | FC/APC standard fiber optic connector |
| Operational Lifetime | >20 years |
| Customization Parameter | Available Options | Recommended Applications |
| Temperature Range | Standard: -40°C to +240°CExtended High: Up to +300°CExtended Low: Down to -80°C | Standard range for most transformer applicationsExtended high range for overload monitoringExtended low range for cryogenic applications |
Confirm measurement points before ordering.
Verify available mounting locations and cable routes.
Define power supply, protocol and cabinet requirements.
It provides condition data for the monitored transformer subsystem so operators can trend changes, configure alarms and plan follow-up inspection.
Yes. Sensor count, measurement channels, communications and enclosure options are reviewed against the project specification.
Integration depends on the selected model and protocol. Include the required interface and data map in your inquiry.
Retrofit feasibility depends on sensor access and the transformer design. Some measurements are non-invasive, while direct winding probes are normally installed during manufacture or overhaul.
Email the transformer type, voltage class, monitored points, required outputs, installation stage and project quantity to FUZHOUINNO.

Multi-channel hot spot acquisition for phase, winding and cooling-zone comparison.

A dielectric fluorescent probe intended for installation near selected transformer winding locations.

Transformer winding temperature monitoring configured for rail power and traction environments.
Plan transformer monitoring installation from drawings and sensor placement through wiring, commissioning, baseline capture and handover.
Plan transformer monitoring sensor types, locations, channel counts, spare capacity, identifiers and commissioning records before procurement.
Understand direct and indirect transformer winding temperature monitoring methods, sensor placement, channel planning, limits and applications.
Final specifications, interfaces, accessories and installation arrangements are confirmed for the selected model and order.