Transformer Oil Condition Monitoring System
Integrated visibility into transformer oil temperature, level, pressure and configurable condition inputs.
Local indication and remote signal options for conservator oil level and temperature.

Local indication and remote signal options for conservator oil level and temperature.
FUZHOUINNO reviews the sensor arrangement, channel count, installation environment and communication requirements for each transformer project.
Request Product Configuration| Output signal: | Pt100 platinum resistance signal, 4-20mA current signal (AC/DC220V or DC24V power supply). |
|---|---|
| Working conditions: | Environmental temperature (-40~+55) ºC, relative humidity ≤ 95%. |
| Measurement range: | Default (0-150) ºC, optional (0-160) ºC, (-20-140) ºC, (-45-150) ºC, etc., see the minimum and maximum scales on the dial. |
| Accuracy: | Level 1.5, allowable error: ± (measurement range x 1.5%). |
| Switching performance: | Four or six sets of adjustable switches, each set of switches can be set freely within the full range. |
| Switch action error: | ± 2 ºC. |
| Poor switch switching: | (5 ± 3) ºC. |
| Rated power of switch: | AC220V/5A, DC110V/3A. |
| Temperature bulb size: | Φ 14 x 150 mm, with an installation thread of (M27 x 2) mm. |
| Capillary length: | Standard configuration of 6m (other tail lengths can be customized) |
| Protection level: | IP55 |
| External dimensions: | 304 * 192 * 103mm |
| Installation dimensions: | Two types, one types is 80mm x 100mm, 4- Φ 8; Another type is 144mm x 210mm, 3- Φ 7 |
Confirm measurement points before ordering.
Verify available mounting locations and cable routes.
Define power supply, protocol and cabinet requirements.
It provides condition data for the monitored transformer subsystem so operators can trend changes, configure alarms and plan follow-up inspection.
Yes. Sensor count, measurement channels, communications and enclosure options are reviewed against the project specification.
Integration depends on the selected model and protocol. Include the required interface and data map in your inquiry.
Retrofit feasibility depends on sensor access and the transformer design. Some measurements are non-invasive, while direct winding probes are normally installed during manufacture or overhaul.
Email the transformer type, voltage class, monitored points, required outputs, installation stage and project quantity to FUZHOUINNO.

Integrated visibility into transformer oil temperature, level, pressure and configurable condition inputs.

IP68 three-in-one transformer monitor for oil temperature, oil level and absolute pressure with RS-485 integration.

Magnetically coupled transformer conservator oil-level indication with configurable remote outputs.
Compare ten transformer parameters commonly monitored online and learn what each signal can and cannot reveal about asset condition.
Compare continuous transformer monitoring with offline diagnostic testing, including coverage, limitations, costs and maintenance decisions.
Evaluate retrofit transformer monitoring options, sensor access, outage needs, interfaces, installation risks and commissioning deliverables.
Final specifications, interfaces, accessories and installation arrangements are confirmed for the selected model and order.